Automation Field Components
100 Ohm (Two Wires) RTD, Immersion, Welded Well, 2.5', Galvanized Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
119436
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/100-2W-I-2.5'-GD - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The galvanized metal box, with well configuration has male 1/2 inch NPT threads. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration. ACI also standardizes with etched Teflon lead wires and 2 part wells for this part. ACI immersion temperature sensors are designed for HVAC, Building Automation Systems, and light industrial applications. Specific applications include: chillers, hot water systems, tanks, and boilers. NOTE: Welded thermowells are not intended for moving water or high pressure service. Fluid velocity and wake frequency are primary factors in well failure. Machined thermowells should be used in these types of applications.
- Negative temperature coefficient
- Double encapsulated sensor
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/MOUNTING CLIP-1/4' - ACI
Automation Field Components
BP 1/4' Mounting Clip
A/20K-PO-12' - ACI
Automation Field Components
20,000 Ohm Thermistor, Probe Only, 12'
A/1K-2W-R2SO-A09-G5 - ACI
Automation Field Components
1,000 Ohm (Two Wires) RTD, Room (R2), Setpoint 0 to 2K Ohms, Override, BLUE/RED Sticker
QTS-61120X-D000000 - ACI
Automation Field Components
Toxic Gas Sensor, Chlorine, 0-3 PPM, 4-20mA Output, loop powered, NEMA1, Duct Mount
CT-R36-A4-U-15M - ACI
Automation Field Components
Revenue Grade CT, Rocoil, 35.4" L, 131 mV /1000A @ 60 Hz, 15 m Leads
A/MLP2-300-P-B-A-C-0P - ACI
Automation Field Components
Differential Pressure, Panel Mount, 300 pascals, BiDirectional, +/- 0.5% FSO, 0-10VDC
A/TUCH2-0-10V-0039 - ACI
Automation Field Components
LCD, RH2%, SET, O/R, DEG F
A/1K-NI-BP-20'Z - ACI
Automation Field Components
1,000 Ohm Nickel RTD, Bullet Probe, 1", 20' Zip WIre