A/BALCO-DO-4' - ACI
Automation Field Components
1,000 Ohm Balco RTD, Duct, Without Box, 4'
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
121876
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/BALCO-DO-4' - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
1K Ohms @ 70 Deg F Balco RTD The standard duct without box configuration has a mounting flange for quick installation and etched-teflon leads. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration. Additional options include: plenum rated cable and quick connects for direct termination to male VAV-Controller inputs.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TTM100-IM-6'-4-GD - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD (NIST Cert), Immersion, Machined Well, 6', Galvanized Enclosure, 4-20mA Output
A/10K-E1-I-4'-GD - ACI
Automation Field Components
10,000 Ohm (E1) Thermistor, Immersion, Welded Well, 4', Galvanized Enclosure
A/1K-NI-FA-12'-4X-NIST - ACI
Automation Field Components
1,000 Ohm Nickel RTD, Flexible Cable Averaging, 12', NEMA 4X Enclosure, NIST Cert
A/RH2-RP2-6'-EH - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, ± 2% Accuracy, 6' Plenum
A/TT100-BP-2-GD-20'CL2P - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD, Bullet Probe, 1", 20' Plenum Cable, Galvanized Enclosure, 2-10VDC Output
EPWG VERSION #4 - ACI
Automation Field Components
Pulse Width Modulation Input (2.93 sec), Pressure Output (0-15PSI), Single Valve, 0.007" Bleed Orifice, Version 4, Gauge, (10, 5, 25 sec), (0-10PSI, 0-20PSI), Reverse Acting
A/TT1K-A-50'-4-4X - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Copper Averaging, 50', NEMA 4X Enclosure, 4-20mA Output
A/RH2-TT1K-D-BB-4 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 2% Accuracy, Transmitter w/ 1,000 Ohm RTD, NEMA 3R (2G) Enclosure, 4-20mA (Temp)