Mini, Fixed Current Switch, Solid Core, NO, 0 to 150A Range, <0.20A Trip Point
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
117852
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/MCS - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The A/MCS and A/MSCS are miniature “Go/No Go” current status switches designed to replace relays in most applications. These switches are small in stature, allowing for tight installations. The output of the A/MCS and the A/MSCS current switches functions as a N/O switch, activated by the amount of sensed AC current. The output of these switches uses a N/O solid-state switch (more reliable than a relay) and is non-polarity sensitive. These units perform in any application where the amount of AC current flow is sufficient to indicate the operating status of the sensed load. The A/MCS and A/MSCS Series are covered by ACI's Five (5) Year Limited Warranty.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TT1K-HT-I-4'-4-BB - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, High Temperature Immersion, Welded Well, 4', NEMA 3R Enclosure, 4-20mA Output
A/CSI-I-2.5'-BB - ACI
Automation Field Components
10,000 Ohm (CSI) Thermistor, Immersion, Welded Well, 2.5', NEMA 3R Enclosure
A/RH2-AN-D-4X-NIST - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 2% Accuracy, 10,000 Ohm Thermistor (Type III), NEMA 4X Enclosure, NIST Cert (Temp)
A/DLP-7K5-P-U-N-A-1-A-0P-S - ACI
Automation Field Components
Differential Low Pressure, 7500 Pascals, Unidirectional, No Display, 0.50% Accuracy, w/ Pitot Tube, 4-20mA Output, No Nist, Standard
Q8-C3H8-100L-O-X - ACI
Automation Field Components
Expl Proof, Smart Sensor, Propane, 0-100% LEL, 3 SPDT Relays, NEMA 4X, 4-20mA, 2-10V, or Modbus RTU
A/TUC2-AN-0043 - ACI
Automation Field Components
10,000 Ohm Thermistor (Type III), Setpoint, w/ Override, LCD
A/10KS-BBS - ACI
Automation Field Components
10,000 Ohm Thermistor, Flush Mount Button, Brass
RN (0-1000) - ACI
Automation Field Components